An Assessment Of The Performance And Maintenance Culture Of The Ahmadu Bello University, Samaru, Zaria Water Treatment Plant – Complete project material

[ad_1]

ABSTRACT

 

he project “An Assessment of the Performance and Maintenance Culture of Ahmadu Bello University, Samaru, Zaria, Water Treatment Plant”aimed at assessing the performance and the maintenance culture of the Ahmadu Bello University Water Treatment Plant (ABU WTP).The technique of survey method, monitoring of treatment process and questionnaires were used to obtain and process the required data. Therefore, each treatment unit was visited and critically examined, treatment processes monitored, leakages along the distribution network monitored for five weeks; and base on this approach, some performance indicators (PIs) were selected and their values were computed and compared with known standards. It was observed that the pump efficiency was 76% which is acceptable. About 1150.2 liters (303.9 gallons) that is 0.024% of water loss as a result of leakage along the pipelinewithin five weeks. The workability of the plant units was 85%, the availability of power at the plant was 95.83% and the average daily time of power supply is found to be 22 hours.The plant uses chlorine as disinfectant and this is acceptable by World Health Organization (WHO).The materials used for the Tanks and Reservoir is of International Standard (Concrete and Block). The maintenance culture predominant in the plant is preventive maintenance. The automatic dosing machine at the plant was unserviceable, hence dosing is done manually, this is not acceptable by international standard. The overall performance of the treatment plant was found to be 50%; this performance is very low comparing to the assessment criteria.

 

TABLE OF CONTENTS

Title Page i Declaration ii Certification iii Dedication iv Acknowledgements v Abstract vi Table of Contents vii List of Figures xi List of Tables xii List of Plates xiii List of Appendices xiv Nomenclature xv CHAPTER ONE: INTRODUCTION 1.1 Background of the study 1 1.2 Problem Statement 2 1.3 Significance of the Study 3 1.4 Aim and Objectives of the work 4 1.5 Scope of the Study 4 1.6 Justification 4 CHAPTER TWO: LITERATURE REVIEW 2.1 Introduction 6 2.2 Purpose of Assessment 6 2.3 General Concept of a Treatment Plant Assessment 7 2.4 Assessment Process 7 2.4.1 Treatment Plant Operation 8 2.4.2 Treatment Plant Performance 8 2.5 Water 8 2.5.1 Sources of Water 9
2.6 Water Treatment 10
VIII
2.6.1 Methods of Treatment 10 2.7 Water Treatment Plant 11 2.8 Design of Treatment Plant Units 13 2.8.1 Aeration Tank 13 2.8.2 Rapid Mixing Flocculation 14 2.8.3 Sedimentation Tank 15 2.8.4 Filtration 15 2.9 Water Transmission 16 2.10 Distribution System design 16 2.11 Design of Service Reservoir 16 2.12 Pumps 17 2.12.1 Pump Power and Efficiency 18 2.12.2 Pump Maintenance/Repair 19 2.13 Pipe 20 2.14 Leakage 20 2.14.1 Leakage Detection 21 2.14.2 Leakage Control 22 2.15 Fundamentals of Maintenance 23 2.16 Maintenance Concepts (MC) 23 2.16.1 Corrective Maintenance (CM)/ Breakdown Maintenance (BDM) 24 2.16.2 Preventive Maintenance 25 2.16.3 Condition-Based Maintenance (CBM) 26 2.17 Performance Measurement 26 2.18 Culture 27 2.18.1 OrganizationalCulture 28 2.18.2 Maintenance Culture 28 2.18.3 Maintenance Organization 29 2.18.4 Maintenance Organization Goals 30 2.18.5 Maintenance Resources 30 2.19 ABU WTP 31 2.20 A Typical Plant 33
IX
CHAPTER THREE: MATERIALS AND METHODS 3.1 Introduction 35 3.2 Materials 35 3.3 Methods 36 3.3.1 Water Treatment Section 36 3.3.1.1 Surveying 36 3.3.1.2 Visitations 36 3.3.1.3 Water Treatment Procedure 36 3.3.2 Electrical Section 41 3.3.3 Mechanical Section 41 3.3.3.1 Determination of Pump Performance 41 3.3.3.2 Assessment of Pipelines 43 3.3.3.3 Leakages 43 3.3.4 Maintenance Culture 44 3.3.5 Data Analysis 44 3.3.5.1 Primary Data Obtained Through Survey Method and Observations 44 3.3.5.2 Operation and Maintenance Performance Indicators 44 3.3.6 Performance Measurement Models (PMM) 46 CHAPTER FOUR: RESULTS AND DISCUSSIONS 4.1 Results 48 4.1.1 Chemical House 48 4.1.2 Treatment Section 48 4.1.3 Mechanical Section 50 4.1.3.1 Pipe Lines 50 4.1.3.2 Leakages 51 4.1.4 Electrical Section 52 4.1.5 Maintenance Section 53 4.1.6 Questionnaire Analysis 53 4.1.6.1 Plant Water Treatment Assessment and Performance 54 4.1.6.2 Plant Maintenance Culture and Assessment 56
4.1.7 Calculation of Performance Indicators 58
X
4.1.7.1 Functioning Treatment plant Units PIs 59 4.1.7.2 Routine Monitoring of Water Quality PIs 59 4.1.7.3 Percentage Sample Fail to Meet Quality Standard 59 4.1.7.4 Percentage Treatment Capacity Utilized PIs 59 4.1.7.5 Percentage Population Served PIs 59 4.1.7.6 Availability of Power Supply PIs 60 4.1.8 Performance Measurement Models Calculation 60 4.1.8.1 Availability 60 4.1.8.2 Treatment Plant Performance 60 4.2 Discussion 61 4.2.1 Chemical House 61 4.2.2 Treatment Section 61 4.2.3 Mechanical Section 62 4.2.4 Electrical Section 64 4.2.5 Treatment Performance 65 CHAPTER FIVE: SUMMARY, CONCLUSION AND RECOMMENDATIONS 5.1 Summary 67 5.2 Conclusions 67 5.3 Recommendations 69 5.4 Contributions to Knowledge 69 References 71 Appendices 77
XI

 

 

CHAPTER ONE

INTRODUCTION 1.1 Background of the Study Drinking water is a fundamental requirement of the human body. Good quality drinking water is primarily sourced from rainfall or from surface water sources such as streams, rivers, springs, and lakes (IWMI, 2000). Where these surface waters do not exist or where they exist in quantities that cannot adequately support the dependent populations, ground water resources are exploited in the form of wells and boreholes to provide this vital body requirement (Adakole and Abulodi, 2011).Water has and continues to be the center of ancient and present day civilizations for sustenance (Anon,2004). Water occupies about 75% of the earth’s surface. Freshwater (surface water) resources are limited to less than 30% of the earth‘s hydrosphere, making potable water still more limiting (Newcome et al., 2005). Rainfall is the primary source of water. Before present day developments and in some rural areas in developing countries, rain water is still relatively very clean and it is directly abstracted for drinking and used for other domestic purposes without any significant consequence (Bellamy et al., 2000). Rainwater flows into streams, rivulets, rivers and lakes which are referred to as surface water sources (Cornwell and Macphee, 2001).
Also, under heavy and sustained rainfall, rainwater ponds on the ground and slowly infiltrates and percolates through layers of porous strata until it reaches impervious stratum where it forms pools to become ground water (Young,2006). Globally, all sources of water are inter-related in a continuous circulation known as the hydrological cycle in which surface water, ground water, seas and oceans are influenced by meteorological interactions like evaporation, transpiration and edaphic movements (infiltration and percolation). The water environment – including the oceans, rivers, streams, groundwater, all seas and adjacent
2
coastal areas – forms an integrated whole that is an essential component of the global life-support system. Recent climatic changes have resulted in extreme conditions of floods, landslides and droughts, which have in some regions become disastrous in their consequences (WHO, 1994). It is vital for human being to have cleandrinking water. This is why the Ahmadu Bello University community drinking water in Samaru-Zaria must meet many different quality standards and has to go through a sequence of maintenance to have an efficient performance. Surface water withouttreatment cannot be used as municipal drinking water because it has high concentration of natural organic matter (NOM) which can be harmful for human health and can form intolerable reactions or biological growth in distribution systems (Aboludeet al.,2009). Hence, without adequate maintenance culture, the water treatment plant performance can never be of acceptable standard. It is against this backdrop that the present work is concerned with the assessment of the performance and maintenance culture of the Ahmadu Bello University, Samaru-Zaria water treatment plant for efficient supply of drinking water. It is a work geared towards evaluating the operations of ABU water plant in terms of pump efficiency, quality of treated water, water pipelines, tanks and reservoir. 1.2 Problem Statement
The heavy burden of shortage of water treatment and distribution by the negligence in maintaining the plant systems gave birth to the idea of maintenance culture of water treatment plant. The development of expensive, complex and highly-developed equipment, and machinery which led to the need to achieve higher product quality, longer machine life, higher machinery effectiveness and operational safety, has motivated the effort to improve maintenance concepts(Al-Najjaret al., 2001).
3
Also, one of the major challenges associated with water treatment plant is leakages along the distribution lines. While efforts are being made to improve the supply situation, poor maintenance culture is paid toward minimizing the losses, particularly leakages due to faulty fittings (Lambert, 2002). Iron corrosion is one the most complicated and costly problems facing the plant drinking water facilities. Water treatment is one of the most challenging and complex systems that municipalities need to deal with considering limited resources. A study from mid-90s showed that the continuously deteriorating Nigerian water supply system would require N3.1 billion to bring the system at satisfactory level. Unfortunately, since the commissioning of ABU water works in 1981, the Ahmadu Bello University water supply plant is still at Phase-I state, while the entire campus population has increased tremendously (Tukura et al., 2011). This means that the supply currently may be inadequate orthe plant maintenance has been neglected. 1.3 Significance of the Study The result of this research issues is very expedient in view of the following: Firstly, adequate understanding about the quality treated water distributes by of Ahmadu Bello University water treatment plant, the pump efficiency, the leakage rate, volume of water loss per weekand the predominant maintenance culture at the plant. Secondly, the research will suggest way of reducing the volume of water leakage along the pipelines. Also, findings of the study will contribute much needed information on the effective maintenance culture at the ABU WTP.
4
1.4 Aim and Objectives The aim of this research is to assess the performance and maintenance culture of Ahmadu Bello University water treatment plant for efficient delivery of portable drinking water. The Specific objectives of this research therefore are as follows:
i. To access the Ahmadu Bello University Samaru Zaria water treatment plant processes and the predominant maintenance culture.
ii. To assess the pump efficiency and performance indicators of the Ahmadu
Bello University, Samaru-Zaria water treatment plant.
iii. To determine the plant’s operational efficiency in terms of staff, quality of
treated water and rate of leakages and causes. 1.5 Scope of the Study The scope of the present research was to study the performance and maintenance culture of the ABU water treatment plant by assessing the plant’s components like tanks, pumps, treatment process, pipelines and quality of treated water. A questionnaire was used to assess the maintenance culture predominant in the plant. This study was not in any position to medically investigate and examine the type of diseases associated withdisinfectants by-products (DBPs)or the potential health effects associated with long term exposure already documented in literature (Adakoleet al., 2011). 1.6 Justification
Machines, buildings and other service facilities are subject to deterioration due to their use and exposure to environmental conditions. Process of deterioration, if unchecked culminates in rendering these facilities unserviceable and brings them to a standstill. The task
5
of maintenance is to keep the above in satisfactory condition, according to standard set by management, keeping in view the cost aspect also. Water treatment is one of the most challenging and complex systems that municipalities need to deal with considering limited resources. Such will constitute a basis for advocacy for an appropriate agency of school to supervise water treatment. Proper maintenance culture will enhance efficient functioning of the plant components for adequate delivery of portable drinking water to the end users.
6

GET THE COMPLETE PROJECT»

Do you need help? Talk to us right now: (+234) 8111770269, 08111770269 (Call/WhatsApp). Email: [email protected]

IF YOU CAN’T FIND YOUR TOPIC, CLICK HERE TO HIRE A WRITER»

Disclaimer: This PDF Material Content is Developed by the copyright owner to Serve as a RESEARCH GUIDE for Students to Conduct Academic Research. You are allowed to use the original PDF Research Material Guide you will receive in the following ways: 1. As a source for additional understanding of the project topic. 2. As a source for ideas for you own academic research work (if properly referenced). 3. For PROPER paraphrasing ( see your school definition of plagiarism and acceptable paraphrase). 4. Direct citing ( if referenced properly). Thank you so much for your respect for the authors copyright. Do you need help? Talk to us right now: (+234) 8111770269, 08111770269 (Call/WhatsApp). Email: [email protected]

[ad_2]


Purchase Detail

Hello, we’re glad you stopped by, you can download the complete project materials to this project with Abstract, Chapters 1 – 5, References and Appendix (Questionaire, Charts, etc) for N4000 ($15) only, To pay with Paypal, Bitcoin or Ethereum; please click here to chat us up via Whatsapp.
You can also call 08111770269 or +2348059541956 to place an order or use the whatsapp button below to chat us up.
Bank details are stated below.

Bank: UBA
Account No: 1021412898
Account Name: Starnet Innovations Limited

The Blazingprojects Mobile App



Download and install the Blazingprojects Mobile App from Google Play to enjoy over 50,000 project topics and materials from 73 departments, completely offline (no internet needed) with the project topics updated Monthly, click here to install.

Read Previous

Spectral Decomposition Of Compact Operators On Hilbert Spaces – Complete project material

Read Next

Biochemical Effect Of Fibrinogen – Complete project material